Skills Station Six
Supplemental Oxygen Administration
This station is designed to test your
ability to correctly assemble the equipment
needed to administer supplemental oxygen in
the prehospital setting. This is an
isolated skills test. You will be
required to assemble an oxygen tank and
regulator and administer oxygen to the
patient using a nonrebreather mask.
Because the patient cannot tolerate the
mask, at this point, you will be instructed
to discontinue oxygen administration by the
nonrebreather mask and start oxygen
administration using a nasal cannula.
Once you have initiated oxygen
administration using a nasal cannula, you
will be instructed to discontinue oxygen
administration completely.
You have (5) five minutes to complete
this skill station.
Interface Features / Options
- Review this skill
and information
- Take the skill
knowledge test
|
Skills Station
Details |
|
Takes or verbalizes, body
substance isolation precautions |
1 |
|
Assemblies the regulator to the
tank |
1 |
|
Opens the tank |
1 |
|
Checks for leaks |
1 |
|
Checks tank pressure |
1 |
|
Attaches a non-rebreather mask
to oxygen |
1 |
|
Prefills the reservoir |
1 |
|
Adjusts the liter flow to 12
liters per minute or greater |
1 |
|
Applies and adjusts the mask to
the patient's face |
1 |
|
NOTE: The examiner
must now inform the candidate
that the patient is is not
tolerating the non-rebreather
mask. Medical direction
has ordered you to apply a nasal
cannula. |
|
Attaches the nasal cannula to
oxygen |
1 |
|
Adjusts the liter flow to 6
liters per minute or less |
1 |
|
Applies the nasal cannula to the
patient |
1 |
|
NOTE: The examiner
must now advise the candidate to
discontinue oxygen therapy. |
|
Removes the nasal cannula from
the patient |
1 |
|
Shits off the regulator |
1 |
|
Relieves the pressure within the
regulator |
1 |
|
TOTAL: |
15 |
|
CRITICAL
CRITERIA
___ Did not take,
or verbalize body substance
isolation precautions
___ Did not
assemble the tank and regulator
without leaks
___ Did not
prefill the reservoir bag
___ Did not
adjust the device to the correct
liter flow for the non-rebreather
mask
___ Did not
adjust the device to the correct
liter flow for the nasal cannula
|
|
|
Skills Station Testing
Knowledge
Based Skills Testing
|
Skills
Knowledge Test |
|
Practical Skills Summary Test
Once you have reviewed the
practical skill above, you may
take a knowledge based test to
ensure that you know the skill. |
4 Questions
Take the Test Now |
|
|
|